Turbine mass flow meter manufacturer by Bjssae: When to use a volumetric flow meter or a mass flow meter? A volumetric flow meter is recommended when high accuracy is not required when measuring gas volumetric flow. However, when comparing results, a volume flow meter requires additional temperature and pressure compensation. Mass flow meters, on the other hand, measure flow rate independent of gas pressure and temperature. As a result, mass flow measurements are more reliable, accurate, and repeatable. See more details on turbine mass flow meter.
Influence of humidity on measurement results when using vortex meter. The output of the vortex flowmeter is only proportional to the flow velocity of the fluid flowing through the measuring tube. When measuring wet saturated steam, the influence of water droplets on the output of the turbine flow meter is negligible, so it can be considered that the output of the turbine flow meter is entirely caused by the wet flow. Caused by the dry part of the steam. The density of the dry part, whether it is pressure compensation or temperature compensation, can be detected more accurately. The results of steam measurement are often used as the basis for economic settlement between the supply and demand sides. If the two parties agree to settle the fee according to the dry part of the steam and no charge for the condensed water, the impact of the phase change on the measurement is negligible and can be ignored.
Second, the gas turbine flow meter equipment has strong functions, low power consumption and superior performance. When it is sold in the industry, it is found that the functional advantages of this kind of flowmeter will be more perfect. In many gas distribution stations or gas When promoting in the station, I found that the advantages will be more diversified, and there are more and more advantages. Third, the configuration of the natural gas turbine flow meter instrument is more perfect, and it will be more and more widely used. As long as you take a fancy to the above clarity, it will be more convenient in the process of normal use. After this is used in many gas distribution stations, it is found that the measurement accuracy is higher.
Ultrasonic flow meters enable users to perform flow measurement inspections at many points in the flow process without the need for permanent installation. This universal driving time timer has a dual-function button interface, an ergonomic handheld design, and a beautiful backlit color digital display that greatly simplifies setup and data collection. Compared with other traditional flowmeters or high temperature ultrasonic flow meter, it has the characteristics of high accuracy, high reliability, high performance, and low cost. The flowmeter also has other advantages: TVT technology design. Fewer hardware components, low-voltage broadband pulse transmission, and low power consumption. Clear, user-friendly menu selections make the flowmeter easy to use. Daily, monthly and yearly total traffic. The parallel operation of positive, negative, and net flow is displayed cumulatively by a scale factor (span) and a 7-digit number. Find extra info on bjssae.com.
Sincerity, excellence in coriolis flow meter production with 33 years experience, Since 1987.Through continuous research, development and transformation, we have become the leader of the Coriolis Mass Flow Meters industries in China.Our products including coriolis mass flow meter,thermal mass flow meter,fork density meter and etc.We have 100+ workers and 5000+ factory,our customers from all over the world. We support OEM coriolis mass flow meter name plates.
The vortex flow meter is more commonly used in steam flowmeters now, with temperature and pressure compensation, and the measured result is mass flow. However, due to different environments, steam is divided into superheated steam and saturated steam. These are all possible changes in the density of steam, which will affect the measurement results. After the above-mentioned evaporation occurs, the former one has no effect on the compensation, only the dry part of the steam increases, and the dryness increases accordingly. The latter situation means that the saturated steam becomes superheated steam. At this time, the influence on the flow meter is divided into three types.
Day for day vast quantities of oil and gas are transported across the globe, refined and transported further. Mature and foolproof technology is essential. But it is the control through instrumentation and visualisation that help make all these processes safe and reliable. The Coriolis Insertion Density Meters could be used for the detection of the liquid’s density. The insertion density meters are the best choices for the proccess control as the basic parameters of density, and also for the quality control with the solid percentage or the concentration for references.