LEV testing and monitoring tips

Soldering produces a narrow but expanding directional rising plume of fume with a high concentration gradient making it a high strength source. The plume of fumes is highly variable and prone to disturbance by ambient air movements. Uncontrolled soldering causes high personal exposures in the breathing zone; this can be 20 – 50 times the S.T.E.L dependant on the soldering scenario. This can equate to exposures exceeding the 8-hour TWA W.E.L after only 15 minutes of soldering. General ventilation at 5 air changes per hour (ach) per hour was not sufficient to control personal exposures, but was capable of reducing background exposures within the test room.

“Every employer who provides any LEV to meet regulation 7 shall ensure that, it is maintained in an efficient state, in efficient working order, in good repair and in a clean condition – Regulation 9.1 COSHH” Where engineered controls have been used the employer must ensure that they are tested and thoroughly examined with a suitable record kept for minimum of 5 years. Further more the regulation states that: “Any LEV system must be thoroughly appraised and tested at least once every 14 months. – Regulation 9.2. This is reduced to 6 months in certain circumstances.”

As LEV is a control measure under COSHH Regulations it must be regularly and thoroughly inspected and tested. As stated above, LEV regulations outline that any employer who uses local exhaust ventilation to control hazardous substances must ensure that it is operating effectively. Local Exhaust Ventilation Testing is a legal requirement in the UK. All equipment must be thoroughly examined and tested by a competent person at least every 14 months to ensure employees are safe.

Equipment that draws pollutants from an operation or process in the working environment. Made up of an inlet like a hood, slit, arm, cabinet or booth. This will be located near to or close to the area of the substance release. All suchlike equipment needs to be connected by ducting and a fan to enable the movement of air. The removed air passed through a filter or is extracted to atmosphere away from the workplace. How Welding Supplies Direct can help ? WE will carry out a thorough tests in line with COSHH Regulation 9 as detailed in HSE Guide HSG258 Our levels of service can be tailored to your Companies needs. However, most clients choose to take advantage of by combining servicing with the LEV testing. Read more details on https://www.weldingsuppliesdirect.co.uk/welding-equipment/lev-testing.html.

Where employers use or intend to use LEV they must ensure that it is appropriate for the task, installed and operated correctly and subsequently maintained so it continues to operate as when originally installed. Suppliers of LEV can play an important role in helping the employer with the design, installation and maintenance of the equipment. This guidance is therefore intended to help employers and suppliers as well as managers, trade union and employee safety representatives to work together to provide effective LEV so that workers are not breathing in hazardous substances. Different chapters will be more appropriate for different audiences.